FUSE REPLACEMENT
To replace fuses unscrew the four internal hex screws, and then remove the front cover as shown in figure 65
and 66. Check fuses with an amp meter to locate the blown fuse. Replace the fuse with one of exactly the
same size as shown in figure 67 and 68. Replace the cover and tighten the internal hex screws.
FRONT COVER
10 AMP FUSES
2 AMP FUSES
70 AMP FUSE
FOR BATTERY
SHORT CIRCUIT
PROTECTION
INTERNAL HEX SCREW
Fig. 65
Fig. 66
Fig. 67
Fig. 68
MAINTENANCE
Figure 67
Fuse Part No.
8-28-05019 (American-Lincoln)
ACK-70 (Cooper Bussmann)
Figure 68
Fuse Part Nos.
2-00-05861 (American-Lincoln/2 amp)
ABC-2 (Cooper Bussmann/2 amp)
2-00-05860 (American-Lincoln/10 amp)
ABC-10 (Cooper-Bussmann/10 amp)
These fuses are manufactured by: Cooper-Bussmann, Inc., P.O. Box 14460, St. Louis, MO 63178-4460